SE-2800 & HS-2800

How to re-calibrate the t-bar on the SE-2800 & HS-2800?

How to re-calibrate the t-bar on the SE-2800 & HS-2800?

How to re-calibrate the t-bar on the SE-2800 & HS-2800?

Nov 03 2020 | SE-2800 & HS-2800

Q: How do I re-calibrate the t-bar on my SE/HS-2800?
A:
Please follow the following steps –

  1. Move the T-Bar to its lowest position.
  2. Power OFF the SE/HS-2800 switcher
  3. Press and hold down button 1 on both the Program and Preset rows of the switcher’s keyboard
  4. Power ON the SE/HS-2800 switcher while still holding down the buttons in step 3.
  5. The switcher will start but the keyboard lights will remain dead except for the T-Bar progress LEDs. When these LEDs flash ON and OFF release the buttons from step 3.
  6. Move the T-Bar to its highest position and then press the CUT button.
  7. Move the T-Bar back to its lowest position and then press the AUTO TAKE button.
  8. To exit the calibration procedure press the CLOCK button.
  9. Ensure the TIMER button is OFF.
  10. Test the T-Bar.

These instructions can also be found on page 38 of a product manual.

ADDITIONAL
SE-2800 & HS-2800

WHAT CAN WE HELP YOU WITH??

Datavideo support is here to help.