Log into the NVS-25 server in the web browser using our IP Finder or your preferred method
If you cannot find or connect to your NVS-25, please follow this guide and return to this article when connected
Click Settings tab and turn off the Stream Server
Click Apply
Click on the Settings tab, followed by Firmware Update on the Settings sidebar
Select Firmware and navigate to the firmware file "A"
Click the Start button to begin the update
When complete the browser window will read "Firmware Update Success!!"
Select Firmware Update again and navigate to firmware file "B"
Click the Start button to complete the upgrade
Power off and on the NVS-25 when the browser window prompts you.
It may display a countdown before it is safe to restart.
Please note that if the "B" file takes longer than normal to apply, give it 10 minutes, power cycle the unit, and double-check that the firmware version on the status tab matches the version you downloaded.